Test Kit Chloride

Determination of chloride. Range 0 – 400 ppm.
<!–

Equipment & reagents

  • EDT018 65 ml Plastic Test Bottle
  • SDT023 BC1/CC1 Indicator
  • SDT026 BC2 High Range Titrant

–>

Category:

Product Descrption

Drops of reagent BC2

Chloride as mg/l Cl

Notes

1

20

Maintain daily blowdown

2

40

3

60

4

80

5

100

Acceptable chlorides in low-pressure boiler

6

120

7

140

8

160

9

180

10

200

11

220

12

240

13

260

14

280

15

300

16

320

Reduce chlorides by increased blowdown

17

340

18

360

19

380

20

400

Testing Procedure

1. Fill the test jar with 20 ml of cooled sample. Note: If measuring boiled water, use the tested sample from step 3 of the alkalinity test.

2. Add 4 drops of reagent BC1/CC1. The sample will turn yellow.

3. Add drops of reagent BC2 one at a time until a pale orange colour appears. Count the number of drops used. Each drop is equivalent to 20 mg/l chloride.

Note: If measuring boiler water it is possible to use the completed alkalinity test sample and follow instructions from step 2 above.